53
10.1.3. Filter number settings
[MicB] FBS
AUTO:DYN 7 :
5
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the number of filters to be used for
Auto and Dynamic modes.
• Filters are assigned to both modes from 12 filters in total.
• Filters used for Auto and Dynamic modes are assigned to Auto
mode followed by Dynamic mode in order of filter number as
shown below.
[Example for "AUTO : DYN 7 : 5" (default setting)]
10.1.4. Dynamic mode filter initialization
[MicB] FBS
CLEAR DYN OK
?
PARAMETER
PUSH-ENTER
CHANGE
• All filters set for the Dynamic mode are initialized when the
Setting knob is pressed.
• To cancel the function, press the or shift key, and the
screen changes to display the previous or next setting item.
10.1.5. Auto mode filter initialization
[MicB] FBS
CLEAR AUTO OK
?
PARAMETER
PUSH-ENTER
CHANGE
• All filters set for the Auto mode are initialized when the Setting
knob is pressed.
• To cancel the function, press the shift key, and the screen
returns to display the previous setting item.
10.1.2. Auto mode activation
[MicB] FBS
AUTO START OK
?
PARAMETER
PUSH-ENTER
CHANGE
• Press the Setting knob to automatically search for the feedback
points and set the filters for feedback suppression. (Auto mode)
• Both the FBS (Feedback suppression) and the LOCK (System
lock) indicators flash during Auto mode operation.
• To interrupt the Auto mode operation, press the Setting knob.
• When the number of filters is set to "0" for Auto mode, the
indication "Can't use Auto" is displayed on the LCD screen,
disabling the Auto mode activation.
• To cancel the function, press the or shift key, and the
screen changes to display the previous or next setting item.
Filter No. 123456789101112
Mode Auto mode Dynamic mode
[Example for "AUTO : DYN 8 : 4"]
Filter No. 123456789101112
Mode Auto mode Dynamic mode
• Even when the number of filters is changed, filters are not
initialized.
For example, when filter assignment is changed from "AUTO :
DYN 7 : 5" to "AUTO : DYN 8 : 4" (refer to the above setting
examples), Filter 8 operation mode is switched to Auto mode,
however, keeping the filter parameters once set by Dynamic
mode operation.
The Filter parameters and Mode confirmation display (next page)
remain unchanged as those for Dynamic mode till Auto mode is
activated.