TOA Electronics D-901 Stereo Receiver User Manual


 
34
8.12. Level Sense Settings
The level sense refers to a parameter used to adjust the sensitivity by which the gate detects an input signal
level. Proper attack time settings prevent the gate function from being accidentally triggered by pulse noise.
(Refer to the next page.)
Attack time Release time
Compressor settings (p. 31) or Auto-leveler settings (previous page)
Gate settings (next page)
[ IN 1] Level
RELEASE 200
m
s
[IN 1] Level
ATTACK 0 .2
m
s
[Screen display operations]
8.12.1. Attack time settings
[IN 1] Level
ATTACK 0 . 2
m
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the attack time.
Parameter setting range: 0.2 ms 5 s (Refer to p. 86 for more
information.)
Pressing an Input channel selector key permits the level sense
attack time to be set for that channel. The [IN 1] indication
changes to the selected channel number indication.
The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
8.12.2. Release time settings
[IN 1] Level
R E L E A S E 2 0 0
m
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the release time.
Parameter setting range: 10 ms 5 s (Refer to p. 86 for more
information.)
Pressing an Input channel selector key permits the level sense
release time to be set for that channel. The [IN 1] indication
changes to the selected channel number indication.
8.11.4. Release time settings
[IN 1] LEVELER
R E L E A S E 1 . 0
0
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the release time.
Parameter setting range: 100 ms 10 s (Refer to p. 86 for more
information.)
Pressing an Input channel selector key set for the auto-leveler
mode permits the auto-leveler release time to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.