8.11. Auto-Leveler Settings (only when the auto-leveler mode is selected in Section 8.9.)
The auto-leveler function performs to keep the output level constant by suppressing the change of sound
volume. Setting the target level (the constant level to be automatically adjusted to) and the maximum gain (the
amount of gain to bring the lower level to the target level) automatically compensates for the input level. Note
that setting an excessive amount of gain increases the input sensitivity, easily causing feedback.
Note: No following displays appear when the compressor mode is selected.
ON
When any of the following screens is displayed, the auto-leveler function for the displayed channel
can be enabled or disabled with the function ON/OFF key. When enabled (ON), the function
ON/OFF Indicator lights.
Maximum gainTarget level Attack time Release time
Compressor/auto-leveler mode selection (p. 31)
Level sense settings (next page)
[ IN 1] LEVELER
T ARGE T + 0 d
B
[IN 1] LEVELER
MAX GA I N +0dB
[IN 1] LEVELER
ATTACK 500
m
s
[IN 1] LEVELER
R E L EA S E 1 . 0
0
s
[Screen display operations]
8.11.1. Target level settings
[ IN 1] LEVELER
TARGET +0d
B
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the target level.
Parameter setting range: 20 to +10 dB in 1 dB steps
Pressing an Input channel selector key set for the auto-leveler
mode permits the auto-leveler target level to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.
The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
8.11.2. Maximum gain settings
[IN 1] LEVELER
MAX GAIN +0d
B
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the maximum gain.
Parameter setting range: 0 to +20 dB in 1 dB steps
Pressing an Input channel selector key set for the auto-leveler
mode permits the auto-leveler maximum gain to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.
8.11.3. Attack time settings
[IN 1] LEVELER
ATTACK 500
m
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the attack time.
Parameter setting range: 10 ms 10 s (Refer to p. 86 for more
information.)
Pressing an Input channel selector key set for the auto-leveler
mode permits the auto-leveler attack time to be set for that
channel. The [IN 1] indication changes to the selected channel
number indication.