TOA Electronics A-9060DH Stereo Amplifier User Manual


 
35
EVENT01 IN1
Input channel name
Input channel setting
Set the input channel using the Input channel selection key.
The name of the set input channel is displayed on the screen.
EVENT01
O
UT1
Output channel setting
Output channel name
Select the output channel using the Output channel selection key, then confirm the selection by setting the
Output channel ON/OFF key to ON (the output channel indicator, red dot on the VFD screen lights).
The name of the set output channel is displayed on the screen.
Repeat above operations to set multiple outputs.
11.4.3. Event setting items
EVENT01 N
O
NE
Event number selection and Event classification settings
Event number
Event classification
The flashing portion is the cursor position. Use the Left and Right shift keys to move the cursor on this screen.
Choose the Event number from 1 32, and the Event classification from "NONE," "ROUTE," "BASE," and
"BGM END."
NONE: Invalidates the selected Event.
ROUTE: Sets broadcast patterns consisting of input/output, trigger, and other settings.
BASE: Groups broadcast patters which have been set to "Priority 8 Input with Trigger set to NONE " in
Classification ROUTE, so that they may be activated with a single trigger. This classification is
normally used to set the Event of BGM broadcasts.
BGM END: Used to perform settings for terminating all Events to which inputs with priority 8 are assigned.
Note
Screens that appear when the Up or Down shift key is pressed differ depending on the Event classification
settings.
Trigger setting (when Event classification is set to ROUTE)
EVENT01TRI
G
C- IN01
Set how to activate the selected Event.
C-IN1 to C-IN04 (C-IN1 to C-IN2 when the C-001T module is used):
Closing the designated control input terminal activates the Event.
VOX: The event is activated when the selected input channel receives a signal.
Note
The D-001T module must be used for input, and the VOX set to ON in the audio input setting.
NONE: External control cannot be used for activation. Set the trigger setting here to NONE when designating
the selected Event number as a BGM pattern.