Functions assignable to P.Input1 to P.Input5 (input terminals)
Indication Function
PLAY/PAUSE The same function as HX button on the
main unit
PLAY The same function as H button on the
remote
PAUSE The same function as X button on the
remote
STOP The same function as x button
AMS + The same function as > button on the
remote
AMS The same function as . button on the
remote
FF The same function as M button
REW The same function as m button
MARK The same function as MARK button on the
remote
LOCATE The same function as LOCATE button
EJECT The same function as A EJECT button on
the main unit
Fader PLAY Performs Fader Play (page 19)
1 Track PLAY
to 20 Track
PLAY
The same function as numeric buttons on
the remote
OFF No operation
Functions assignable to P.Output1 to P.Output3 (output
terminals)
Indication Function
PLAY Grounding during playback on the player
PAUSE Grounding during pause on the player
NO DISC Grounding during no disc in the disc
compartment
OFF Always floating
Do the procedure below to change the function of each
terminal.
1 Press the MENU/EXIT button while the player is
stopped.
MENU Mode appears in the display.
2 Rotate the AMS control until Parallel appears in
the display, and then push the control.
If Parallel is already set to User, skip this step
and step 3, and go to step 4.
3 Rotate the AMS control until User appears in the
display, and then push the control.
4 Rotate the AMS control until the terminal that you
want to assign function to (e.g., P.Input1 or
P.Output2) appears in the display, and then push
the control.
5 Rotate the AMS control until the function that you
want to assign to the terminal that you selected
appears in the display, and then push the control.
To assign functions to more terminals, repeat steps
4 and 5.
6 Press the MENU/EXIT button to complete the
setting.
Notes
When Preset is selected for Parallel, you cannot
select terminals or assign functions to them. To
enable the assigning of functions to terminals, first
select User for Parallel.
Doing the procedure above with Preset selected for
Parallel allows you to check the factory setting for
each terminal.
Electrical specifications for the
PARALLEL connector
Input terminals
Input system Make contact
Input ON voltage Less than 0.5 V
Input OFF voltage More than 3 V
Opening terminal voltage
5 V
Input pulse width More than 100 msec
Input standing voltage
0.5 to +10 V
Output terminals
Output system Open collector for NPN transistor
Remaining voltage at ON
Less than 0.5 V
Maximum current at ON
100 mA
Standing voltage 20 V