Chapter 10
Setup Menus
10-20
Chapter 10
Setup Menus
10-4 Items in the Extended Setup Menu
Item number Item name
Settings
608 PHASE CORRECTION
Select whether or not to carry out phase correction control on the LTC generated
by the time code generator.
OFF : No control
ON: Carry out control.
609 TCG CF FLAG Select whether or not the color framing flag is set in the blank bit of the time code
data.
OFF : Color framing flag is not set.
ON: Color framing flag is set.
AUTO: Color framing flag is set or not depending upon the color framing phase
relationship between the recorded video signal and the time code signal.
When AUTO is selected, color framing is controlled as follows according to the
operating mode of the time code generator.
• In INT PRESET mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to PRESET
in function menu page 1, and in modes other than the automatic editing mode):
the time code signal is generated with color framing locked to the video signal,
and the color framing flag is set.
• In INT REGEN mode (F1 (TCG) is set to INT and F2 (PR/RGN) set to LTC or
VITC in function menu page 1, and in the automatic editing mode), and also in
EXT mode (F2 (PR/RGN) is set to EXT): the time code signal is generated
without color framing locked to the video signal, and the color framing flag is not
set.
610 REGEN CONTROL
MODE
Select whether or not the time code is automatically regenerated.
AS&IN : In automatic editing carried out in either assemble mode or insert mode
with this unit as the recorder, regardless of the settings of F1 (TCG) and F2
(PR/RGN) in function menu page 1, the time code generator regenerates
according to the time code on the tape.
ASSEM: In automatic editing carried out in assemble mode with this unit as the
recorder, regardless of the settings of F1 (TCG) and F2 (PR/RGN) in function
menu page 1, the time code generator regenerates according to the time code
on the tape.
MANU: Regardless of whether this unit is the recorder or player, the time code
generator operates in accordance with the settings of F1 (TCG) and F2 (PR/
RGN) in function menu page 1.
FULL: Whether local or remote and regardless of the settings of F1 (TCG) and
F2 (PR/RGN) in function menu page 1, when any of the ASSEMBLE, VIDEO,
CH1 to CH4, CUE and TC buttons is lit, the time code generator regenerates
according to the time code played back from the tape.
617
LTC OUTPUT PHASE
SELECT
Set the output phase of time code signals (LTC).
TCG/R : Output the playback time code signal during playback.
When the edit preset function is on, and when recording, output the time code
signal generated by the internal time code generator.
INPUT: Use the same phase as the input video.
OUTPUT: Use the same phase as the output video.
AUTO: Use the same phase as the input video when editing, and use the same
phase as the output video at other times (playback, recording, etc.)
618 UPCONV EMBEDDED
VITC (HDW-M2000 only)
Select the source time code for HD-SDI embedded VITC which is output after
subjected to up-conversion during playback of SD-format tape.
when
VITC : Select VITC recorded on SD-format tape.
LTC : Select LTC recorded on SD-format tape.
Menu items in the range 600 to 699, relating to the time code generator (Continued)