Sony HCD-C5 Stereo System User Manual


 
40
HCD-C5
7. INITIAL SETTING OF ADJUSTMENT VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile memory
to the initial setting value. However the results of the temperature compen-
sation offset adjustment will not change to the initial setting value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to 4. Precautions for Adjustments
(See page 36) and execute the initial setting before the adjustment as re-
quired.
Procedure:
1. Press the . R or > R button to display ADJ
CLEAR (C28).
2. Press the ENTER/YES R button. Complete! will be
displayed momentarily and initial setting will be executed, after
which ADJ CLEAR (C28) will be displayed.
8. RECORDING AND DISPLAYING THE IOP
INFORMATION
The IOP data can be recorded in the non-volatile memory. The IOP
value on the optical pick-up label and the IOP value after the
adjustment will be recorded. Recording these data eliminates the
need to read the label on the optical pick-up.
Recording Procedure:
1. Press the . R or > R button to display Iop Write
(C05), and press the ENTER/YES R button.
2. The display becomes Ref=@@@.@ (@ is an arbitrary
number) and the numbers which can be changed will blink.
3. Input the IOP value on the optical pick-up label.
To select the number : Press the . R or > R button.
To select the digit : Press two buttons of VOL - and
CD Z simultaneously.
4. When the ENTER/YES R button is pressed, the display
becomes Measu=@@@.@ (@ is an arbitrary number).
5. As the adjustment results are recorded for the step 4 value. Leave
it as it is and press the ENTER/YES R button.
6. Complete! will be displayed momentarily. The value will be
recorded in the non-volatile memory and the display will become
Iop Write (C05).
Display Procedure:
1. Press the . R or > R button to display Iop
Read(C26) and press the ENTER/YES R button.
2. @@.@/##.# is displayed and the recorded contents are
displayed.
@@.@ indicates the IOP value on the optical pick-up label.
##.# indicates the IOP value after adjustment
3. To end, press the MENU/NO R button to display Iop Read
(C26).
9. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C. Per-
form it immediately after the power is turned on when the internal tempera-
ture of the unit is the same as the ambient temperature of 22 ˚C to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Procedure:
1. Press the . R or > R button to display TEMP
ADJUST (C03).
2. Press the ENTER/YES R button to select the TEMP
ADJUST mode.
3. TEMP = [OK] and the current temperature data will be
displayed.
4. To save the data, press the ENTER/YES R button.
When not saving the data, press the MENU/NO R button.
5. When the ENTER/YES R button is pressed, TEMP =
SAVE will be displayed and turned back to TEMP ADJUST
(C03) display then. When the MENU/NO R button is pressed,
TEMP ADJUST (C03) will be displayed immediately.
Specified Value:
The TEMP = should be within E0 - EF, F0 - FF, 00 -
0F, 10 - 1F and 20 - 2F.
10.LASER POWER ADJUSTMENT
Before starting adjustment;
The laser power adjustment value changes depending upon the types
of the optical pick-up (KMS-260B or KMS-260E).
Check the type of the optical pick-up before starting adjustment.
(See the illustrations The method of identifying the optical pick-
up on page 41.)
Check the IOP value of the optical pick-up before adjustments.
(Refer to 8. Recording and Displaying the Iop Information)
Connection:
Procedure:
1. Insert the laser power meter probe into the disc insertion slot
and set it on top of the objective lens of the optical pick-up.
(When it cannot be set properly, press the
m R button or
M R button to move the optical pick-up)
Connect the digital voltmeter to CN105 pin 1 (I+3V) and
CN105pin 2 (IOP) on the BD (MD) board.
2. Press the . R or > R button to display LDPWR
ADJUST (C04).
(Laser power : For adjustment)
3. Press the ENTER/YES R button once to display LD 0.9 mW
$ .
4. Press the . R or > R button until the laser power
meter reading matches with the specified value as described in
the following table.
Press the ENTER/YES R button after setting the range knob
of the laser power meter, and save the adjustment results.
(LD SAVE $ will be displayed for a moment)
5. Then LD 7.0 mW $ will be displayed.
+
BD (MD) board
digital voltmeter
CN105 pin
1
(I+3V)
CN105 pin
2
(IOP)
Optical pick-up
objective lens
laser
power meter
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW