Sony HCD-C5 Stereo System User Manual


 
30
HCD-C5
CHECKS PRIOR TO PARTS REPLACEMENT AND ADJUSTMENTS IN MD
Before performing repairs, perform the following checks to determine the faulty locations up to a certain extent.
Details of the procedures are described in 5 Electrical Adjustments.
0.9 mW power
Specified value : figure1
7.0 mW power
Specified value : figure2
Iop (at 7.0mW)
Labeled on the optical pick-up
Iop value ± 10mA
Unsatisfactory if displayed as NG: XXXX
(X is an arbitrary number)
Unsatisfactory if displayed as T=@@ (##) [NG]
(@@, ## are both arbitrary numbers)
Laser power check
(6-2 : See page 37)
Auto check
(6-4 : See page 38)
Temperature
compensation
offset check
(6-1 : See page 37)
Criteria for Determination
(Unsatisfactory if specified value is not satisfied)
Clean the optical pick-up
Adjust again
Replace the optical pick-up
Replace the optical pick-up
Replace the optical pick-up
Check for disconnection of the circuits around D101
(BD (MD) board)
Check the signals around IC101, IC151, CN102, CN103
(BD (MD) board)
Measure if unsatisfactory
Note:
The criteria for determination above is intended merely to determine if satisfactory or not, and does not serve as the specified value for adjust-
ments.
When performing adjustments, use the specified values for adjustments.
Figure1:
Figure2:
RETRY CAUSE DISPLAY MODE IN MD
In this test mode, the causes for retry of the unit during recording can be displayed on the fluorescent indicator tube. During
playback, the track mode for obtaining track information will be set.
This is useful for locating the faulty part of the unit.
The following will be displayed :
During recording and stop : Retry cause, number of retries, and number of retry errors.
During playback : Information such as type of disc played, part played, copyright.
These are displayed in hexadecimal.
Precedure:
1. Load a recordable disc whose contents can be erased into the unit.
2. Press the MENU/NO R button. When Edit Menu is displayed on the fluorescent indicator tube, press the
. R or > R button to display All Erase?.
3. Press the ENTER/YES R button.
4. When All Erase?? is displayed on the fluorescent indicator tube.
5. Press the ENTER/YES R button to display Complete!.
6. Press the REC/REC IT button to start recording. Then press the u button and start recording. If recording cannot be performed,
press the FUNCTION z button and set a different function.
7. Press three buttons of VOL - , u and CD SYNC HIGH simultaneously to enter the retry cause display mode.
8. To check the track mode, press the u button to start playback.
9. To release this mode, press the ?/1 button to turn the power off. When TOC goes off, disconnect the power plug from the
outlet.
If the test mode cannot be released, refer to Factory Preset on page 24.
SPECIFIED VALUE
KMS-260B
KMS-260E
6.8 to 7.2 mW
7.0 to 7.5 mW
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW