Sony HCD-C5 Stereo System User Manual


 
28
HCD-C5
Function
u
x
M R
m R
x + >/M TUNING +
VOL - + CD Z
MD Z
REPEAT R
Contents
Sets continuous playback when this is pressed in the STOP state. When this is pressed during continu-
ous playback, playback position moves.
Stops continuous playback and continuous recording
The sled moves to the outer circumference only when this is pressed
The sled moves to the inner circumference only when this is pressed
Switches the spindle servo mode (CLV S y CLV A)
Switches the displayed contents each time the button is pressed
Ejects the disc
Releases the test mode
7. AUTOMATIC SELF-DIAGNOSIS FUNCTION
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical pick-up.
To perform this test mode, the laser power must first be checked.
Perform AUTO CHECK after the laser power check and Iop Compare.
Procedure:
1. Press the . R or > R button to display AUTO CHECK (C01).
2. Press the
ENTER/YES R button. If LDPWR is displayed, it means that the laser power check has not been
performed. In this case, perform the laser power check and Iop Compare, and then repeat from enter the MD test mode.
3. If a disc is in the mechanical deck, it will be ejected forcibly.
DISC IN will be displayed in this case. Load a test disc (MDW-74/GA-1) which can be recorded.
4. If a disc is loaded at step 3, the check will start automatically.
5. When XX CHECK is displayed, the item corresponding to XX will be performed.
When 060 CHECK completes, the disc loaded at step 3 will be ejected. DISC IN will be displayed. Load the check disc
(TDYS-1).
6. When the disc is loaded in step 5, the check will automatically be resumed from 07 CHECK.
7. After completing to test item 12 (oC CHECK), check OK or NG will be displayed. If all items are OK, CHK ALL OK will
be displayed. If any item is NG, it will be displayed as NG:xxxx.
When CHK ALL OK is displayed, it means that the optical pick-up is normal. Check the operations of other parts (spindle
motor, sled motor, etc.).
When displayed as NG:xxxx, it means that the optical pick-up is faulty. In this case, replace the optical pick-up.
8. INFORMATION
Display the software version.
Procedure:
1. Press the . R or > R button to display INFORMATION (C31).
2. Press the ENTER/YES R button.
3. The software version will be displayed.
4. Press the MENU/NO R button to end this mode.
6. FUNCTIONS OF OTHER BUTTONS