Polycom C8 Speaker System User Manual


 
Command Protocol Reference Guide
A - 73
dp_gate_en Enable Gate
Description
This parameter enables (1) or disables (0) the gate function of the dynamics
processor. This parameter and dp_en must be enabled for the gate to function.
dp_gate_hold Gate Hold Time
Description
This parameter sets the amount of
time (in milliseconds) the input signal level
must be below the gate threshold before the gate begins to decay.
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Conferencing Line Output,
Sound Reinforcement Mic/Line Input, Sound Reinforcement
Line Output, Analog Telephony Input, Analog Telephony
Output, Submix, ConferenceLink Aux Input, ConferenceLink
Aux Output
Virt Chans Mono, Stereo
Default 0
Argument Argument value
Channel Type Virtual Channel
Value Type Integer
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Conferencing Line Output,
Sound Reinforcement Mic/Line Input, Sound Reinforcement
Line Output, Analog Telephony Input, Analog Telephony
Output, Submix, ConferenceLink Aux Input, ConferenceLink
Aux Output
Virt Chans Mono, Stereo
System Limits Minimum: 1, Maximum: 2000
Default 500
User Limits
Supported
No