TERMINATING FOUR-PAIR TWISTED CABLE
The Select
™
and Solo
™
Master Keypad Modules, the Expander, and the ZR-8630AV unit’s system-expansion con-
nections require a four-pair twisted cable with a one-to-one wiring configuration. To maintain consistency
throughout all IntelliPad
®
Ci installations, we recommend the color-coding pattern described in Figure 31, but
you may adopt a different color-coding pattern if you use it consistently throughout the system. IMPORTANT:
use VW-1 rated wire for connection to KEYPADS and 12V OUT terminals.
47
CONNECTIONS
1234
Pair 2
Pair 1
T568A
Pair 3 Pair 4
567
8
1 = Green/White
2 = Green
3 = Orange/White
4 = Blue
5 = Blue/White
6 = Orange
7 = Brown/White
8 = Brown
Figure 31
Select
™
Master
Keypad Module
Numeric
™
Accessory
Keypad Module
RJ-45 Connector
for connection to Master
Keypad Module
RJ-45 Connector
for connection to
Numeric
™
Accessory
Keypad Module
RJ-45 Connector
for connection to
IR Sensors
RJ-45 Connector for
connection to
the ZR-8630AV
Included
Jumper Cable
IR SENSOR
INPUT
OUTPUT
SYSTEM
ACCESSORY
KEYPADS
INPUT
OUTPUT
Transport
™
Accessory
Keypad Module
Figure 32
Figure 33
CONNECTING ACCESSORY
KEYPADS
Jumper cables (included) mate each
Master Keypad Module with an
optional Accessory Keypad Module.
(See Figure 33.) The Select
™
Master
Keypad Module mates with both
accessory modules; the Solo
™
mates
only with the Numeric
™
.
CONNECTING THE MASTER KEYPADS TO THE HOME RUN OF
FOUR-PAIR TWISTED CABLE
Terminate the home run of four-pair twisted cable with a male
RJ-45 connector. Plug it into the rear-panel SYSTEM jack on the
Select
™
, Select
™
IR, Solo
™
, or Solo
™
IR Master Keypad Module (see
Figure 32).