Kenwood TM-V71E Stereo System User Manual


 
84
1 Enter Menu mode and access Menu 518 (DAT.SPD) {page 20}.
2 Set the data speed to 1200 or 9600 bps.
PC PORT SPEED
You can adjust the speed at which the computer and transceiver exchange
information, when the transceiver is connected to your computer.
1 Enter Menu mode and access Menu 519 (PC.SPD) {page 20}.
2 Set the PC port speed to 9600, 19200, 38400, or 57600 bps.
Turning the power ON/OFF will change the port speed setting.
SQC OuTPuT SETTINg
You can set the condition for which the SQC output terminal becomes active.
1 Enter Menu mode and access Menu 520 (SQC.SRC) {page 20}.
2 Set the SQC output activation method to one of the following:
OFF: SQC output remains inactive.
BUSY: When a signal is received on the data band, the SQC output becomes active.
SQL: While CTCSS/DCS is ON and a matching signal is received, the SQC output
becomes active. While CTCSS/DCS is OFF, the SQC output becomes active when
a busy signal is received.
TX: While transmitting, the SQC output becomes active.
BUSY.TX: When the conditions of BUSY and TX (above) are met, the SQC output
becomes active.
SQL.TX: When the conditions of SQL and TX (above) are met, the SQC output
becomes active.
Note: The activation type (logic) can be changed using the MCP-2A software.