P 64 Digital Audio Matrix
Owner’s manual
6.1 Specifications/Technische Daten
GENERAL DESCRIPTION AND FEATURES
P 64 Digital Audio Matrix Modular P 64 Audio Matrix including signal processing,
routing, system control and supervision
Audio 32 Audio Channels
4 Audio Slots, modular
8-Channel Input and Output cards, analog or digital
Networking Module Slot for optional CobraNet™ Interface
32 I/O Audio and Control
Safety / Redundancy Internal Supervision, System Monitoring, Watchdog, Fault
Output, Redundant Audio Network possible
PC Configuration and Control Software IRIS-Net - Intelligent Remote & Integrated Supervision
Integration of P 64, Remote Amplifiers, peripheral control
Configuration, Control and Supervision for complete Audio
Systems
Freely programmable User Control Panels and Access Le-
vels
AUDIO SPECIFICATIONS
Frequency Response 20 Hz...20 kHz (-0.5 dB)
Signal to Noise Ratio (A-weighted) AI-1: 117 dB typical
AO-1: 118 dB typical
P 64 analog In to analog Out: 115 dB typical
THD+N < 0.005 %
Signal Delay AI-1: 1.3958 ms
AO-1: 0.646 ms
P 64 analog In to analog Out: 2.2917 ms
Crosstalk < -110 dB @ 1 kHz
SIGNAL PROCESSING
Sample Rate 48 kHz internal
32 kHz - 192 kHz external
Data Format 24 Bit linear A/D and D/A conversion, 48 Bit processing
Signal Processing 2 DSPs Standard (150 MHz, 300 MIPS)
1 DSP per Audio Module (100 MHz, 100 MIPS)
DSP-1 Extension Module optional (+300 MIPS)
INTERFACES
Ethernet 10 / 100 MBit/s, RJ-45 (PC Control)
CAN 10... 500 kbit/s, 2 x RJ-45 (Remote Amp Control)
RS-232 2 Ports, 9pin D-Sub female (Remote Control)
USB USB Type B on Front Panel (PC Control)