1.4 Installation instruction
The P 64 has to be set up and installed so that both air supply and ventilation are ensured on
both sides of the device. The direction of ventilation is from left to right when you look at the front
faceplate. Devices with an opposing routing of air flow should not be installed in the same rack.
When installing the P 64 in a rack, a free air duct between the sides of the P 64 and the side
panel of the rack to the upper rack ventilation must be observed in order to ensure sufficient air
ventilation. There must be at least 100 mm free space for ventilation above the rack.
Standard installation rails should be used when mounting an P 64 in transport racks in order to
prevent twisting of the front faceplate.
The P 64 must be protected against: dripping/splashing water, direct solar radiation, high
ambient air temperature or direct impact of heat sources, high moisture, heavy vibrations and
dust deposit.
If these conditions cannot be ensured permanently, maintenance is obligatory at regular intervals
in order to prevent any breakdowns which are mainly due to negative environmental influences.
If the P 64 is transported from a cold to a warm environment, moisture may condense at the core.
The device should not be started up before warming to the changed temperature (approx. after 1
hour). If a solid or liquid is in the housing, cut the device off from the mains power at once and
have the device checked by an authorized service center before re-using it.
1.5 IRIS-Net
The IRIS-Net (Intelligent Remote & Integrated Supervision) PC software is used to configure and
operate the P 64 Audio Matrix. The configuration of the P 64 can be done offline (i.e. without
connection between the PC and the P 64) on the PC. After the connection between the PC and
the P 64 has been established via Ethernet, the configuration can be transmitted to it. In addition
to configurations, IRIS-Net can also be used for extensive supervision, control and monitoring of
P 64 Matrix Managers (and DYNACORD Remote Amplifiers which are connected to them).
The latest version of IRIS-Net is available at www.dynacord.com.
Please see the short IRIS-Net instruction in the menu: > .
ATTENTION:
The maximum ambient air temperature of +40°C should not be exceeded in order to en-
sure failure-free operation.