Barco PGWU-618 Home Theater System User Manual


 
3. Commands
Pos
Size
Name Description
Content
0x00
PW392 (hex)
0x01
DDP442x (hex)
0x08
PIC (hex)
0x0C
Lan module (hex)
0x10
Waveform (hex)
2 1 to data index
0x14
EDID (hex)
major version (MS B) (hex)
major version (LSB ) (hex)
build number (M SB ) (hex)
build num ber (hex)
build num ber (hex)
3-8 6 version
Each v ersion consists of 6 bytes:
- Byte 0- 1: m ajor v ersion num ber
- Byte 2-3: build number
- Byte 4-5: build number
build number (LS B) (hex)
3.50 get warp keystone vertical, read
About this command
This command gets the warp keystone vertical value.
Request
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj warp
0xA1
adj warp (hex)
2 1 w a rp keystone vertical
0x01
warp keystone vertical (hex)
Response
Pos Size Name Description Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj warp
0xA1
adj warp (hex)
2 1 w a rp keystone vertical
0x01
warp keystone vertical (hex)
3 1 keystone v alue range 0->40
(OSD range -20->20)
keystone value (hex)
3.51 increment noise reduction, write
About this command
This command increments the noise reduction by one .
Request
Pos Size Name Description Content
0 1 inc adj byte value known as "inc adj"
0x22
inc adj (hex)
1 1 adj noise reduction
0x73
adj noise reduction (hex)
R5905746 COMMAND CATALOG 06/01/2014 35