3. Commands
3.48 g et V start, read
About this command
This c omm and gets the vertical start pix el for the VGA and BNC inputs.
Request
Pos Size Name Description Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 get V start
0x12
get V start (hex)
Response
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 get V start
0x12
get V start (hex)
2 1 V start value range 0->20
(OSD range -10->10)
V start value (hex)
3.49 get versions, read
About this command
This command is used to get the version(s).
Request
Pos
Size
Name Description
Content
0 1 get versions
0x60
get versions (hex)
0x00
PW392 (hex)
0x06
DDP442x (hex)
0x0C
PIC (hex)
0x12
Lan Module (hex)
0x18
Waveform (hex)
11
from data index
0x1E
EDID (hex)
0x00
PW392 (hex)
0x01
DDP442x (hex)
0x08
PIC (hex)
0x0C
Lan module (hex)
0x10
Waveform (hex)
2 1 to data index
0x14
EDID (hex)
Response
Pos Size Name Description Content
0 1 get versions
0x60
get versions (hex)
0x00
PW392 (hex)
0x06
DDP442x (hex)
0x0C
PIC (hex)
0x12
Lan Module (hex)
0x18
Waveform (hex)
1 1 from data index
0x1E
EDID (hex)
34 R5905746 COMMAND CATALOG 06/01/2014