3. Commands
3.31 get lamp runtime, read
About this command
This command gets the runtime of the lamp.
Request
Pos Size Name Description Content
01lamp
0x76
lamp (hex)
1 1 get lamp runtime
0x90
get lamp runtime (hex)
0x01
lamp1(hex)
0x02
lamp2(hex)
0x03
lamp3(hex)
2 1 lamp number
0x04
lamp4(hex)
Response
Pos
Size
Name Description
Content
01lamp
0x76
lamp (hex)
1 1 get lamp runtime
0x90
get lamp runtime (hex)
0x01
lamp1(hex)
0x02
lamp2(hex)
0x03
lamp3(hex)
2 1 lamp number
0x04
lamp4(hex)
MSB (hex)
BYTE 1 (hex)
BYTE 2 (hex)
3-6 4 lamp runtime
runtime in hours as DWORD
LSB (hex)
3.32 get lamp status, read
About this command
This command gets the status o f the lamp(s).
Request
Pos Size Name Description Content
0 1 get lam p status
0x67
get lamp status (hex)
1 1 get lam p status
0x40
get lamp status (hex)
Response
Pos
Size
Name Description
Content
0 1 get lam p status
0x67
get lamp status (hex)
1 1 get lam p status
0x40
get lamp status (hex)
0x00
lamp (s) off (hex)
2 1 lamp status
0x01
lamp(s) on (he x)
R5905746 COMMAND CATALOG 06/01/2014 27