Barco PGWU-618 Home Theater System User Manual


 
3. Commands
Pos
Size
Name Description
Content
1 1 adj dimming
0x0D
adj dim ming (hex)
0x00
276.4W (hex)
0x01
300W (hex)
0x02
321W (hex)
0x03
343.1W (hex)
0x04
360W (hex)
0x05
378W (hex)
0x06
400W (hex)
0x07
420W (hex)
0x08
442W (hex)
2 1 dimming value
lamp power (Watt)
0x09
462W (hex)
3.16 get display mode, read
About this command
This command gets the display mode of the active source.
Request
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj display mode
0x15
adj display m ode (hex)
Response
Pos Size Name Description Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
1 1 adj display mode
0x15
adj display m ode (hex)
0x00
presentation (hex)
0x01
video (hex)
2 1 display mode status
0x02
bright (hex )
3.17 get format, read
About this command
This command gets the input format of the active source.
Request
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
11
adj input format
0x14
adj input format (hex)
Response
Pos
Size
Name Description
Content
0 1 get adj byte value known as "get adj"
0x21
get adj (hex)
11
adj input format
0x14
adj input format (hex)
R5905746 COMMAND CATALOG 06/01/2014 19