115
TROUBLESHOOTING
ADDITIONAL
INFORMATION
■ AUTO SETUP
Before AUTO SETUP
During AUTO SETUP
Error message Cause Remedy
See
page
Connect MIC! Optimizer microphone is not connected.
Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
32
Unplug HP! Headphones are connected. Unplug the headphones.
—
Error message Cause Remedy
See
page
E-1:NO FRONT SP
Front L/R channel signal(s) is (are) not
detected.
Select the front speakers with SPEAKER A or B.
—
Check the front L/R speaker connections. 15
E-2:NO SURR.SP A surround channel signal is not detected. Check the surround speaker connections. 15
E-3:NO PRNS SP A presence channel signal is not detected. Check the presence speaker connections. 15
E-4:SBR->SBL
Only right surround back channel signal is
detected.
Connect the surround back speaker to the LEFT
SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.
15
E-5:NOISY Background noise is too loud.
Try running AUTO SETUP in a quiet environment.
—
Turn off noisy electric equipment like air conditioners
or move them away from the optimizer microphone.
—
E-6:CHECK SUR.
Surround back speaker(s) is (are)
connected, though surround L/R speakers
are not.
Connect surround speakers when you use (a)
surround back speaker(s).
15
E-7:NO MIC
The optimizer microphone was unplugged
during the AUTO SETUP procedure.
Connect the supplied optimizer microphone to
OPTIMIZER MIC jack on the front panel.
32
E-8:NO SIGNAL
The optimizer microphone does not detect
test tones.
Check the microphone setting. 32
Check the speaker connections and placement. 15
E-9:USER CANCEL
The AUTO SETUP procedure was
cancelled due to user activity.
Run AUTO SETUP again. 32
E-10:INTERNAL
ERROR
An internal error occurred. Run AUTO SETUP again. 32