Xantech MRC88M Stereo System User Manual


 
Model MRC88m / MRAUDIO8x8m Page: 63
© 2009 Xantech Corporation
IR ROUTING
(Factory Default = “ENABLED”)
This mode allows selective control of multiple same-brand same-model components such as multiple DVD
players or Satellite receivers. When “ROUTING ENABLE” is selected, IR commands are directed only to the
specific emitter output for the source selected in a zone, and not to the other source emitter outputs. When
“ROUTING DISABLE” is selected, IR commands are directed to ALL emitter outputs. The COMMON emitter
output will always output all IR commands.
BACK-LIGHT CONTROL
(Factory Default = 6 seconds)
This setting adjusts the duration that the Keypad LCD display and Buttons will remain lit after a keypad button
press. Back-lighting is variable from ‘Always On’ to ‘Always Off’ or it can be set to time-out after 1 - 10 seconds
in one second increments. This setting will set the backlighting for ALL keypads in the system. IR codes
generated by remote controls received at the keypads IR Receiver do not activate backlighting.
1. Click “ALWAYS ON” to backlight a zone’s keypad(s) for as long as the zone is ON. Backlight turns off
when the zone is turned OFF. Useful in dark rooms.
2. Click “ALWAYS OFF” keypad(s) backlight will never turn on. This is useful in rooms that are always
brightly lit.
3. Click “TIMED” and use the ‘Timed Back-light Control’ Pulldown Menu to set backlight duration from 1-
10 seconds.
MODE OF OPERATION
(Factory Default = “WHOLE HOUSE MODE”)
W
HOLE HOUSE MODE
This mode allows any zone to be able to select and control any source at any time.
P
RIORITY LOCKOUT MODE
When ENABLED, if Zone 1 selects a source, Zone 1 will maintain exclusive control over that source until Zone
1 either selects another source or is turned OFF. Zones 2-8 (2-16 for EXPANDED) can monitor the source, but
cannot control that source until released by Zone 1. Once Zone 1 has released the source, if the source is re-
selected by one of Zones 2-4, that zone will take control and will then have priority.
EXPANDED OPTIONS
(Factory Default = “Not Expanded”)
N
OT EXPANDED
This mode is for systems operating with ONE MRC88m Controller/Amplifier (8 Zones or less). This is the
DEFAULT mode of operation.
E
XPANDED
This mode is for systems operating with TWO MRC88m Controller/Amplifiers connected via the units Expansion
ports. This is for systems with 9 to 16 Zones.
When changing to the Expanded mode a message stating “Please Wait” will appear on screen. Dragon Drop-
IR™ will take about ten seconds (depending on computer speed) to update. The Zones, Controller and Zone
Linking tabs will now open the options for sixteen zone programming and configuration.