Model BXAUDIO4X4 Page: 7
© 2005 Xantech Corporation
7. Sequence Button. Pressing the button allows a single additional IR Command to be learned creating a
Sequence of Commands (also called a Macro). Up to 5 commands may be programmed in this manner
making a macro of up to 6 commands in-all.
8. Delay Button. Adds timed delays in 1 Second increments between IR commands when in Sequence
Mode. A Maximum of 7 Seconds may be entered between commands. Delay can only be entered after
an initial IR Command is successfully learned.
9. Delete Button. Allows Deleting of complete Macros placed under a single Keypad button or a Sources
Power Management Macro.
10. PGM/RUN Switch.
a. UP position places BXAudio Controller in Program Mode (Allows programming of Keypad
Button macros and Power Management commands).
b. DOWN position places BXAudio Controller in RUN Mode.
11. Program Keypad LED.
a. GREEN when system is in Program Keypad Mode
b. ORANGE when in Program Mode and second TOGGLE IR command is expected
c. Blinks RED when an IR Macro command is not successfully learned.
12. Power Management LED. Illuminates GREEN when in POWER ON Macro mode and RED when in
POWER OFF Macro mode.
13. Expansion LED
a. RED – Indicates Unit is in Expanded Mode and is designated as the MASTER Unit.
b. ORANGE - Indicates Unit is in Expanded Mode and is designated as the SLAVE Unit.
c. OFF - Indicates Unit is NOT in Expanded Mode (4 Zone System).
14. STATUS LED. Illuminates GREEN when unit is ready to receive a Macro IR command during the
programming process.
15. Zone LED’s
System Status (Power-Up Mode)
a) Slow Orange Blink – indicates general initialization is occurring.
b) Fast Green Blink – indicates that a keypad on the associated zone is currently being initialized.
c) Fast Red Blink – indicates that the master keypad on the associated zone is not responding to
initialization.
d) Fast Orange Blink – indicates that the slave keypad on the associated zone is not responding to
initialization.
e) All Lights Off – initialization is done, system is ready for operation.
Zone Status (Operational Mode)
a) Steady Green to indicate that Zone is in the Power-Up Mode, is not muted and is not within 5 dB of
MAX-V.
b) Steady Red to indicate that Zone is in the Power-Up Mode, is not muted and is within 5 dB of MAX-V.
c) Flash Green to indicate that Zone is in the Power-Up Mode, is muted and is not within 5 dB of MAX-V.
d) Flash Red to indicate that Zone is in the Power-Up Mode, is muted and is within 5 dB of MAX-V.
e) Flash Green to indicate that Zone is in the Power-Up Mode, is not muted, is not within 5 dB of MAX-V
and is being Ramped Up or Down.
f) Flash Red to indicate that Zone is in the Power-Up Mode, is not muted, is within 5 dB of MAX-V and is
being Ramped Up or Down.
g) Off to indicate that Zone is in the Power-Down Mode.