Telex DN3600C Stereo Equalizer User Manual


 
34
SERVICE INFORMATION
Caution: These servicing instructions are for use by qualified personnel only. To reduce the risk
of electric shock, do not perform any servicing other than that contained in the Operating
Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
Klark Teknik PLC accepts no liability for damage or injury arising from incorrect servicing.
Fuse ratings:
Rear panel fuse holder: 500mAT
MIDI Connections
DN3600 Pro MIDI XLRs correspond to standard MIDI 5-pin DIN connectors thus:
DIN XLR
Pin 5 - data - Pin 3
Pin 4 - +5V - Pin 2
Pin 2 - GND - Pin 1
Voltage Change-Over
The unit automatically adjusts to any input voltage in the range 100 to 240 Vac @ 50 to 60 Hz.
Battery Replacement
Caution!:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent
type recommended by the manufacturer. Discard used batteries according to the manufacturer's
instructions.
Advarsel!:
Lithiumbatteri. Ekxplosionsfare ved feijlagtig handtering af samme fabrikat og type. Lever det
brugte batteri tilbage till leverandoren.