13
MEMORY OPERATION
Equalisation programs may be created from scratch or existing programs may be called up and
modified.
To start from scratch, switch OUT the More EQ and reset the unit by pressing and holding the
Bypass key for more than 5 seconds.
RECALLING A MEMORY
Select Utilities, Memory and Recall in turn on the soft keys. Then use the FREQ rotary control
to select the required memory by number (shown in the NUMBER window) or name (shown,
together with the fader positions, on the LCD screen). Press the Recall key a second time to
complete the procedure. The number of the current memory remains in the NUMBER window.
SAVING A MEMORY
Select Utilities, Memory and Save in turn on the soft keys. The memory number defaults to that
last used, although a new memory location may be entered if desired. Use the FREQ or LEVEL
rotary controls to select the memory location by number, and use the Frequency keys to give the
new memory a name, or to overwrite the previous name. The < key has a backspace function.
The SHIFT key gives access to the numbers 0 to 9. To complete the storage procedure, press the
Save key a second time. The data from both channels is saved to the new location, regardless
of the Link status.
Note: Whenever parameters are adjusted, the revised data is placed in a temporary store so that
the original memory data is not overwritten until it is deliberately saved. When the unit is
switched off, the temporary store is not lost. On switch on, the unit will return exactly to the state
at switch off.