9-3 Alarms
a) With respect to setting of basic menu item 016
During recording and editing operations
REC-PAUSE! on A time code or user bits preset
command was received with recording
paused.
Try the operation again after stopping
recording.
REC mode! on, limit A command to switch video or audio
signals was received during recording.
REC mode! on, limit A command to switch audio channels
was received during recording.
Message in time
data display
Display
condition
a)
Description Action
Message in time
data display
Display
condition
a)
Description Action
Disc Error! on, limit, off Normal recording is not possible
because of a disc defect.
Use another disc.
You can check the state of a disc by
checking playback condition marks (see
page 44).
525/60 sig! on, limit A 525 system SDI signal was input with
this unit in 625 line mode (PAL system)
and with “SDI” selected with the VIDEO
INPUT SEL button.
Input a 625 system SDI signal.
625/50 sig! on, limit A 625 system SDI signal was input with
this unit in 525(U) or 525(J) line mode
(NTSC system) and with “SDI” selected
with the VIDEO INPUT SEL button.
Input a 525 system SDI signal.
A mode err! on, limit An editing operation was attempted on a
recorded disc, when one of the following
audio settings differed from the settings
of this unit.
Number of quantizing bits and
recording channels
Handling of digital audio signals (audio
or non-audio)
To edit this disc, change the following
settings.
Maintenance menu item “AUDIO
CONFIG” – “DATA LENGTH”
Maintenance menu item “AUDIO
CONFIG” – “NON-AUDIO INPUT”
See 8-4-2 “Maintenance Menu Operations”
(page 126) about how to make these
settings.
NON-AUDIO! on, limit An edit preset was attempted on one
channel in an audio channel pair (CH1/2,
CH3/4, CH5/6, CH7/8) when digital
audio signals were set to non-audio.
Insert editing with non-audio signals must
be done on a channel pair. To do insert
editing with audio signals on a single
channel, set maintenance menu item
“AUDIO CONFIG” - “NON-AUDIO INPUT”
to “audio.”
See 8-4-2 “Maintenance Menu Operations”
(page 126) about how to make this setting.
ILL. REF! on, limit, off The playback system and recording
system are not synchronized.
Input a reference video signal to the player
and recorder.
ILL. REC! on, limit A sync error between encoder and input
signal occurred during recording.
Contact your Sony service representative.
ILL. PLAY! on, limit An audio/video phase error occurred
during playback.
MEM. Full! on, limit A memory write error occurred.
MEM. Empty on, limit Playback data in memory was lost, and
playback stopped.