Sony PDW-1500 CD Player User Manual


 
Chapter 9 Maintenance and Troubleshooting
141
9-3 Alarms
MAX # Files on, limit, off The number of files on the disc had
reached the upper limit (5000), or there
was not enough capacity in the General
directory when a command was
received to record, display an E-E
picture, record an essence mark, or add
a quick scene selection sub clip.
Exchange the disc for one with enough
free capacity.
Disc Full! on, limit, off A command was received to record or
display an E-E picture when there was
not enough free capacity on the disc, or
when the number of recorded clips had
reached the upper limit (300).
MAX# SB CLP on, limit, off A command was received to add a sub
clip when the number of registered sub
clips had already reached the upper limit
(300) of the specifications of this unit.
These operations are not possible.
CL OVER DUR on, limit, off A command was received to add a sub
clip when the total duration of sub clips
in the clip list had already reached the
upper limit (24 hours) of the
specifications of this unit.
Disc Damage on, limit, off A command was received to record,
display an E-E picture, record an
essence mark, or add a quick scene
selection sub clip when there was no
free sparing area.
This disc cannot be recorded. Exchange
the disc.
Non AV Full on, limit, off A command was received to record,
display an E-E picture, record an
essence mark, or add a quick scene
selection sub clip when there was no
free Non-Real-Time space.
Insert a different disc with enough free
capacity.
No Clip! on, limit A playback or search command was
received for a disc containing no
recorded clips.
These operations are not possible.
Disc Top! on A PREV or reverse high-speed search
command was received with the disc
stopped at the top.
Disc End! on A NEXT or forward high-speed search
command was received with the disc
stopped at the end.
TC EXT! on A time code or user bits preset
command was received with extended
menu item 626 “TC MODE” set to “ext
preset.”
Try the operation again after setting
extended menu item 626 “TC MODE” to
“int preset.”
See 8-3-2 “Extended Menu Operations”
(page 120) about how to make this setting.
REGEN mode! on A time code or user bits preset
command was received with extended
menu item 626 “TC MODE” set to “int
regen,” “ext regen,” or “rp188 regen.”
Live Logg! on, limit A time code or user bit preset operation
was attempted with extended menu item
258 “LIVE LOGGING” set to “on.”
Set extended menu item 258 “LIVE
LOGGING” to “off” before performing the
operation.
See 8-3-2 “Extended Menu Operations”
(page 120) about how to make this setting.
REC RUN! on A time code or user bits preset
command was received with extended
menu item 627 “RUN MODE” set to “rec
run.”
Try the operation again after setting
extended menu item 627 “RUN MODE” to
“free run.”
See 8-3-2 “Extended Menu Operations”
(page 120) about how to make this setting.
Message in time
data display
Display
condition
a)
Description Action