Sony PDW-1500 CD Player User Manual


 
Chapter 8 Menus
115
8-3 Extended Menu
626 TC MODE Select the time code recording mode.
i-prs (int preset): Set an initial value, then record the output of the
internal time code generator.
i-reg (int regen): Record the output of the internal time code generator,
initialized to time code following continuously upon the time code of
the last frame of the last clip on the disc. When clips files are written
or transferred via a FAM or FTP connection, the time code of the clip
is recorded so that it is continuous with the time code of the last
frame of the last clip on the disc.
e-reg (ext regen): Record the output of the internal time code generator,
synchronized to an external time code generator.
r-reg (rp188 regen): Record the output of the internal time code
generator, synchronized to SMPTE RP188 LTC in an SDI signal.
e-prs (ext preset): Directly record the input of an external time code
generator.
See 4-1-2 “Recording Time Code and User Bit Values” (page 51) for
more information about time code recording modes.
627 RUN MODE When item 626 is set to “int preset,” select the run mode of the internal
time code generator.
free (free run)
: Time code advances continually.
rec (rec run): Time code advances only during recording.
628 DF MODE In 525(U)/525(J) line modes, when item 626 is set to “int preset,” select
the frame mode of the internal time code generator and counter.
df (on (df))
: Drop-frame mode
ndf (off (ndf)): Non-drop frame mode
629 TC SELECT Select the type of time data to show in the time data display, and the type
of external time code when item 626 is set to “ext regen.”
vitc: Display time code as VITC, or select VITC as the external time
code.
tc
: Display time code as TC, or select TC as the external time code.
See 4-1-2 “Recording Time Code and User Bit Values” (page 51) for
more information about selecting external time code.
651 UMID SDI OUTPUT Select whether to output UMID in the VANC of the SDI output.
off: Do not output.
on
: Output.
See 8-3-3 “Using UMID Data” (page 121) for more information about
UMID.
652 UMID SDI VANC LINE Select the line in which UMID is output when menu item 651 is set to “on.”
12 H (12 line), 13 H (13 line), 15 H (15 line), 16 H (16 line), 17 H (17
line), 18 H (18 line), 19 H (19 line) (525(U)/525(J) line modes)
9 H (9 line), 10 H (10 line), 12 H (12 line), 13 H (13 line), 14 H (14 line),
15 H (15 line), 16 H (16 line), 17 H (17 line)
, 18 H (18 line) (625 line
mode)
See 8-3-3 “Using UMID Data” (page 121) for more information about
UMID.
657 ESSENCE MARK SDI OUTPUT Select whether to output essence marks in the SDI output VANC.
off: Do not output.
on
: Output.
660 ESSENCE MARK SDI VANC LINE When item 657 is set to “on,” select the line to which to output essence
marks.
12 H (12 line), 13 H (13 line), 15 H (15 line), 16 H (16 line), 17 H (17
line), 18 H (18 line), 19 H (19 line) (525(U)/525(J) line modes)
9 H (9 line), 10 H (10 line), 12 H (12 line), 13 H (13 line), 14 H (14 line),
15 H (15 line), 16 H (16 line), 17 H (17 line)
, 18 H (18 line) (625 ine
mode)
Menu items in the 600s, relating to the time code, metadata, and UMID
Item number Item name Settings