29
Using the components
Charging the rechargeable batteries
Charging the accupack in the bodypack transmitter
To charge the bodypack transmitter in the EZL 2020-
20 L charging case:
̈
Place the bodypack transmitter with the accupack
inserted into the charging compartment for the
accupack/bodypack transmitter
³
as shown in the
diagram on the left.
When placed into a charging compartment, the
bodypack transmitter automatically switches off.
The red LED CHARGE/ERROR · of the charging
compartment lights up.
When the accupack in the bodypack transmitter is
fully charged, the green LED READY » lights up.
Notes:
y Charging a completely discharged accupack takes
approx. 3½ hours at room temperature.
y Alternatively, you can remove the accupack from
the bodypack transmitter and insert it into the
charging compartment for accupack/bodypack
transmitter ³, as described in the following
section.
y In the charging case, there is no error indication
like the one on the quick charger L 2015 (“red
flashing LED”).
y Only use the charging case for
charging the SK 2020 D bodypack
transmitter, the HDE 2020 D stethoset
receivers and the BA 2015 accupack.
y Never try to charge other rechargeable
batteries or non-rechargeable
batteries.
CAUTION!
»
·