32
INSTALLER
Programming Menu Instructions
Numeric IR Procedure (Optional)
This procedure allows you to program source-specific numeric control functions (e.g., Channel 12, Disk 89) by enabling the Plus and Minus
keys to scroll through channel or disk numbers. The procedure also allows the programming of prefix and suffix commands. Some
source numeric commands require a prefix command such as Channel for a tuner or Disc for a CD changer, or a suffix command such as
Enter or Play. For this reason, it’s important to understand how the source component handles numeric commands from its remote control
before you follow this procedure. See Numeric IR Procedure flow chart on page 49.
To begin the Numeric IR Procedure, select SOURCE SETUP from the top level of the Programming Menu and press Play . At
BASIC SETUP, press Next or Previous three times. At NUMERIC IR, press Play .
1. SOURCE NUM – Select and enter the number of the source for which you want to configure numeric IR.
2. USE NUM IR? – Select and enter Yes to program numeric IR for the source. Select and enter No to disable numeric IR for the
source and advance to SAVE CHANGES (step 7).
3. HIGHEST NUM – Select and enter the highest possible number for the numeric IR function; for example, a 100-disc CD player
would have a highest number of 100.
4. NUMERIC TEXT – Select and enter a label to appear in the scroll list on the keypad display (e.g., Disc, Channel, Preset).
5. PREFIX CMD – Select and enter Yes if the source component needs a prefix command before receiving a numeric command.
Select and enter No to skip the prefix command and advance to SUFFIX CMD (step 6).
a. COMMAND TYPE – Select and enter a command type for the source. Choose one of the following options:
i. Select and enter Default to use the same command type previously selected for the source in BASIC SETUP.
A. KEY FUNCTION – Select and enter the function you want the prefix command to perform (e.g., Disc,
Channel, Preset).
ii. Select and enter Learned IR to use a learned prefix command not included in the default command type. (See
Learn IR Procedure on page 25.)
A. LEARNED SRC – Select and enter the Learned Source location assigned to the source.