Fujitsu DX60S2 CD Player User Manual


 
Chapter 1 Hardware Configurations
1.5 Power Distribution Units (Only for Regions Other than EMEA&I)
ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning-
23
Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0
1.5 Power Distribution Units (Only for Regions Other than
EMEA&I)
There are two sizes for power distribution units: 1U and 2U.
A power distribution unit is an option to connect power supply units to power outlets when power
sockets are limited.
Power distribution unit for DX60 S2 (AC200-240V, 1U, Max 2 enclosures connection)
There are four outlets and two inlets.
Figure 1.26 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection)
The following table shows the specifications of a power distribution unit and the AC cables that
are provided.
Table 1.8 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) and
provided AC cable specifications
Item Specifications
Power Voltage AC200 - 240V
Phase Single
Frequency 50Hz/60Hz
Input cable Connection type IEC60320-C13 NEMA L6-15P
Length 4m
Quantity 2
Output cable Connection type IEC60320-C13 IEC60320-C14
Length 3m
Quantity 4
Outlets (OUTPUT)
Inlets (INPUT)