Chapter 1 Hardware Configurations
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning-
17
Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0
■ Drive interface ports
A DI port is used to connect a drive enclosure.
The following table shows the DI port specifications.
Table 1.2 DI port specifications
■ LAN ports
Two LAN ports (RJ-45) are installed in each controller.
● Regions other than EMEA&I
Each LAN port is used for operation management (MNT port) and for remote support function
(RMT port) respectively.
● EMEA&I region
The MNT port is used for operation management and the RMT port is used for maintenance.
The following table shows the LAN port specifications.
Table 1.3 LAN port specifications
■ SCU
A System Capacitor Unit (SCU) is installed in a controller as a backup power source in case of
power outage.
The SCU is charged from an external power source while the ETERNUS DX Disk storage sys-
tem is running normally. If a power failure is detected, data in the cache memory is saved to the
non-volatile memory in the controller using the SCU. There is no limit to the post-failure data
retention time.
■ PWC ports
A PWC port is installed in a controller.
The PWC port is used to connect a power synchronized unit to perform power synchronization.
The following table shows the PWC port specifications.
Table 1.4 PWC port specifications
Interface
Transfer
speed (max.)
Connector type Number of ports for each controller
SAS 3Gbit/s miniSAS (SFF8088) 1
Interface
Transfer
speed (max.)
Connector type
Number of ports
for each controller
Ethernet
(1000Base-T/100Base-TX/10Base-T)
1Gbit/s RJ-45 2
Interface Connector type
Number of ports for
each controller
RS232C D-sub9 pin 1