Command ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Image recall
Recall an image to buffer
EX!
RF
}
Cim
X!]
Select image
X!
to display.
NOTE: It takes several seconds between the issuance of the recall command (
EX!
RF
}
) and the receipt of the Cim response.
Show the image that is
currently displayed
E
RF
} X!]
The buffer is loaded with image
X!
.
Take
%
Tke
]
Swap the displayed and buffered images using the
selected effect (cut or dissolve).
Switch effect
Set the effect to cut
9*0#
Eff0
]
Set the effect for switching images to cut (immediate).
Set the effect to dissolve
9*1#
Eff1
]
Set the effect for switching images to dissolve.
Read the effect
9#
X@]
Set the dissolve duration
10*
X#
# Dur
X#]
Set the duration of the dissolve effect to
X#
.
Read the dissolve duration
10#
X#]
The dissolve duration is
X#
.
Source selection
Display pass-through
1!
Chn1
]
Display the pass-through input.
Display last image
0!
Chn0
]
Display the previously selected stored image.
View pass-through status
!
X@]
Pass-through mode is
X@
.
Slide show interval
Set slide show interval
2*
X#
# Sli
X#]
Set the display time for each image to
X#
seconds.
Read slide show interval
2#
X#]
The display time for each image is
X#
seconds.
Pass-through configuration
Enable pass-through
1*1#
Pas1
]
Include the pass-through input in the slide show.
Disable pass-through
1*0#
Pas0
]
Do not include the pass-through input in the slide show.
Read the pass-through status
1#
X@]
Show the status of the pass-through.
Auto-switch and slide show mode
Set auto-switch and slide
show mode
4*
X$
# Aut
X$]
Set auto-switch and slide show mode.
X$
definitions:
0 = Off — Auto-switch on loss of pass-through sync
and slide show are disabled.
1 = Off/show — Auto-switch on loss of pass-through
is disabled. Slide show is running.
2 = On/still — On loss of sync on the pass-through
input, auto-switch to display the last-
displayed image until pass-through
sync is restored.
3 = On/show — On loss of sync on the pass-through
input, auto-switch to run the slide
show until sync on the pass-through
input is restored.
Show auto-switch and slide
show mode
4#
X$]
Command and Response Table for SIS Commands
NOTE: X! = Image file name Image name with file extension (*.bmp or *.jpg)
X@ = Cut / dissolve status: 0 = cut 1 = dissolve
Pass-through status: 0 = pass-thu 1 = no pass-thru
X# = Time (duration) 00 – 50 (0.0 to 5.0 seconds) for dissolve duration
000 – 300 seconds for slide show interval
X$ = Auto-switch / slide show 0 = off 2 = on / still
1 = off / show 3 = on / show