IMAGE ADJUSTMENTS August, 2006
3-180
3.19.3 REGISTRATION
Image Area
The image area must be configured
correctly. Adjust the registration within
the adjustment standard range as
described below.
Leading Edge
Adjusts the leading edge registration for each paper type and process line speed.
Side to Side
Adjusts the side-to-side registration for each paper feed station. The side-to-side
registration for the LCT can be adjusted with SP1002 006.
Adjustment Standards
• Leading edge (sub-scan direction): 3 ± 0 mm
• Side to side (main-scan direction): 2 ± 0 mm
Paper Registration Standard
The registration in both main- and sub-scan directions may fluctuate within the
following tolerance.
1st side
• Sub-scan direction: 0 ± 1.5 mm
• Main-scan direction: 0 ± 2 mm
2nd side in duplex
• Sub-scan direction: 0 ± 3 mm
• Main-scan direction: 0 ± 4 mm
A
B
C
B146R966.WMF
Feed direction
Image Area
A = B = C = 4.2 mm (1.6")