P3 = State/details (opt.) P3 only applies if:
P2 = 1 (Power)
If P3 is 0 = Power Off
If P3 is 1 = Power On
P2 = 2 (Error)
P3 = error number
P2 = 5 (Signal Input)
P3 = Input number
P2 = 6 (Signal Channel)
P3 = Channel Number
This optional parameter further
denesthestate.Ifthisis
omitted, assume the event will
reonanysystemeventofthis
type (for example, all signal
input changes rather than a
specicone)
If P1 = F or f Description Meaning
P1 = F or f FUNC key event This is a real-time event that
triggers a command when the
speciedFUNC#ispressed.
P2 = Number key 1-5, 7-9 The number to trigger from.
If P1 = X or x Description Meaning
P1 = X or x System event This deletes a stored event.
P2 = Target * = Delete all events
d = Delete all pending events
waiting because of a DLY
command.
Number = Delete the event
with the given number from
the list
This parameter determines
which events will be deleted.
Examples:
(RTE g 7 H “(GIO 22 P 100)”)
(RTE g 7 H “(GIO 22 P 100) (GIO 1 L)”)
(RTE G 7 H “(GIO 22 P 100) (GIO 1 L)”)
(RTE T 2003/07/09 12:36:45 S "(PWR 1)") = "S" Single / one time
(RTE T 2003/07/09 18:00:00 D "(PWR 0)") = "D" Daily
(RTE T 2003/07/09 05:00:00 W "(PWR 0)") = "W" Weekly
(RTE F 3 “(FRZ 1)”) // freeze image when FUNC-3 pressed
(RTE D 00:05:00 "(PWR 0)") = In 5 minutes, turn the projector off
(RTE G 5 H “(DLY 100) (PWR 0)”) = When pin 5 goes high, delay 100ms, then
power off.
(RTE?)
(RTE!000 T 2003/07/09 05:00:00 S "(PWR 0)")
(RTE!001 T 2003/07/09 12:36:45 S "(PWR 1)")
(RTE!002 T 2003/07/09 18:00:00 D "(PWR 0)")
(RTE?0)
(RTE!000 T 2003/07/09 05:00:00 S "(PWR 0)")
(RTE X 1): delete entry one
(RTE X *): delete all entries
(RTE X d): delete all pending events waiting because of a (DLY) command