25Tact Audio
RCS Menu
Use this menu to select one of the correction presets. M/S-2150 X offers 9 correc-
tion presets as well as bypass. This screen is enabled only if RCS or RCS-SUB
mode is selected (see MODE menu). Correction names are user programmable
from M/S-2150 X windows based application program..
Use this menu to select digital microphone input. Digital microphone input is nor-
mally connected to one of BOZ RCS-16M digital outputs. If microphone is not used
set this option to “---”. In order to avoid positive feedback from the microphone in-
put, selected microphone input can not be used as standard digital input signal..
Use the “UP” and “DOWN” buttons to scroll through all possible options. To select
displayed option press “ENTER” button.
RCS 1: Corr #1
1: Corr #1
1
1 - Correction preset selections.
2 - Active correction preset.
RCS Menu :
2
MEASUREMENT CH: D1
SELECT CH: D1
MSR Menu :
Use the “UP” and “DOWN” buttons to scroll through all possible options. To select
displayed option press “ENTER” button.
To avoid the possibility of getting positive feedback, after the measurements are
completed disconnect microphone from M/S-2150 X input. Positive feedback can
result in excessive output signal level that could potentially damage connected
loudspeaker system.
1 - Measurement input selection.
2 - Edit selected measurement input.
1
2
MSR menu