TacT Audio M/S - 2150 X Stereo Amplifier User Manual


 
17Tact Audio
Biamping - continued
When two or more M/S-2150 X amplifiers are configured in a bi-/tri-amped setup, both
the signal and the RS232 TacT System Bus must be daisy chained between the
amplifiers.
The same signal flow is applicable for both horizontal and vertical bi-amping.
From RCS2.0S, RCS2.2X or
TCS mkII *Optional
From source
AMP-1
AMP-2
AMP-3 - ONLY PRESENT IN TRI-AMPED SETUP
RS232
RS232
RS232
Digital signal
(coax/SPDIF)
Digital signal
(coax/SPDIF)
Digital signal (coax/SPDIF)
usually CD player output.
Connections
With its advanced DSP control, the M/S-2150 X can enable digital crossovers
package (high-pass, low-pass and band-pass) making it possible to configure M/
S-2150 X amplifiers to virtually fit any loudspeaker system.
Examples of how a TacT active system can be configured:
1) Active two-way. The M-2150 X operates as master amp (control unit) and the
S-2150 X operates as normal/slave amp. M-2150 X has a DSP-based high-pass
filter and drives the high-section of the 2-way loudspeaker system. S-2150 X has
a low-pass filter and drives the bass-section of both loudspeakers.
2) Active three-way. Amp 3, M-2150 X (master unit) is set to implement a high-
pass filter and drives the tweeter section. Amp 2 (normal/slave), S-2150 X is set
to implement a band-pass filter and drives the midrange section. Amp 1 (normal/
slave), S-2150 X is set to implement a low-pass filter and drives the bass sec-
tion.
M/S-2150 X
Configurations
M/S-2150 X