Sony MZ-R900 MiniDisc Player User Manual


 
26
MZ-R900
023 0D7603
Remote commander LCD display
03
:Adjusted value
023 0D7800
Remote commander LCD display
00
:Adjusted value
023 0D7801
Remote commander LCD display
01
:Adjusted value
023 0D7900
Remote commander LCD display
00
:Adjusted value
023 0D79E0
Remote commander LCD display
E0
:Adjusted value
023 Patch 01
Remote commander LCD display
01
:Adjusted value
023 ***SDD
Remote commander LCD display
DD
:Adjusted value
65. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
1C.
66. Press the X key.
(0D75 is blinking)
67. Press the [VOL+] key once to change the blinking portion to
0D76.
68. Press the x key.
(00 is blinking)
69. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
03.
70. Press the X key.
(0D76 is blinking)
71. Press the [VOL+] key to change the blinking portion to 0D78.
72. Press the
x key.
(00 is blinking)
73. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
01.
74. Press the X key.
(0D78 is blinking)
75. Press the [VOL+] key once to change the blinking portion to
0D79.
76. Press the x key.
(00 is blinking)
77. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
E0.
78. Press the X key.
(0D79 is blinking)
79. Press the
[DISPLAY] key on the remote commander for sev-
eral seconds (about 3 seconds) to exit the patch data write mode
(to return to the manual mode display in the test mode).
80. Press the X key to write the modified data. (The adjusted value
changes to CC)
81. The modified data writing is over, if the adjusted value changes
to DD.
82. Turn the power off.
Modified Data Writing Method (version 1.200 and later)
1. Select the manual mode of the test mode, and set item number
022 (see page 13).
2. Press the X key to initialize the patch data.
(The modified data writing is over, if the adjusted value changes
to DD)
3. Turn the power off.
023 0D751C
Remote commander LCD display
1C
:Adjusted value
023 0D7600
Remote commander LCD display
00
:Adjusted value
022 PatClr CC
Remote commander LCD display
022 ***SDD
Remote commander LCD display
DD
:Adjusted value