Sony 3-289-204-42(3) Stereo Receiver User Manual


 
102
GB
D:\NORM'S JOB\SONY HA\SO0054\STR-DA2400ES\CEL VERSION\3289204423\04GB-
STRDA2400ESUC\090OTH_GB.fm
masterpage: Left
STR-DA2400ES
3-289-204-42(3)
For details on the Auto Calibration, see “9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)” (page 44).
Refer to “Before you perform the Auto
Calibration” (page 44) before performing the
Auto Calibration.
To operate on the receiver
1
Press GUI MODE repeatedly to select
“GUI OFF”.
2 Press AMP.
Receiver operation is enabled.
3 Press MENU.
4 Press V/v repeatedly to select
“<AUTO CAL>” , then press .
5 Press V/v repeatedly to select
“A.CAL START”, then press to start
the measurement.
Measurement starts in 5 seconds. A count
down is displayed.
Note
While the time is counting down, stand away
from the measurement area to avoid
measurement error.
6 Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.
To cancel Auto Calibration
The measurement will be canceled when you
do the following:
Press ?/1, input buttons or MUTING.
Press SPEAKERS (OFF/A/B/A+B) on the
receiver.
Change the volume level.
Connect the headphones.
Tips
• Operations other than turning the receiver on or off
are deactivated during Auto Calibration.
• The measurements may not be performed correctly
or Auto Calibration cannot be performed when
special speakers, such as dipole speakers are used.
To confirm/save Auto
Calibration when GUI function
is turned off
1
Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display window.
2 Press V/v repeatedly to select the item,
then press .
Performing Auto Calibration
Measurement
result
Display
window
Explanation
When the
measurement
process
completes
properly
COMPLETE
Proceed to step
2.
When the
measurement
process fails
E-
xxx:xx
See “Message
list after Auto
Calibration
measurement”
(page 49).
Item Explanation
RETRY Performs the Auto Calibration
again.
SAVE EXIT Saves the measurement
results and exits the setting
process.
WARN CHECK Displays a warning
concerning the measurement
results. See “Message list
after Auto Calibration
measurement” (page 49).
PHASE INFO. Displays the phase of each
speaker (in phase/out of
phase). See “When you select
“PHASE INFO.””.
DIST. INFO. Displays the measurement
result for speaker distance.
LEVEL INFO. Displays the measurement
result for speaker level.