INSTALLER
INSTALLATION MENU
6. POWER OFF CMD – Tells the controller to turn off the selected source equipment (by
(OfCmd) SOURCE NUMBER) when the last of the UNO System Keypads is
turned off. If “no,” procedure advances to SAVE CHANGES (step 10)
7. COMMAND TYPE – Select the type of source command (e.g., CD, TV, etc.).
(CmdTp)
a. Selected: Learned IR Choose Learned IR if the pre-programmed IR code library does
(LrnIR) not support the source component.
i. LEARNED SRC – Select the learned source bank to be assigned to the source
(LnSrc) component. Procedure advances to KEY FUNCTION (step 9)
b. Selected: Unassigned The Power Off command is cleared. Procedure advances to
(Unasg) SAVE CHANGES (step 10)
c. Selected: Default Default selects the same device type and device code previously
(Deflt) setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 9)
d. Selected: Macro: (To build macros, see Macro Editor page 65)
i. MACRO – Macro loads a series of commands which are processed when
(Macro) activated.
ii. MACRO ID – Enter the macro ID number.Menu advances to SAVE CHANGES
(MacID) (step 10)
e. All Other Selections: Procedure advances to DEVICE CODE (step 8)
8. DEVICE CODE – Source component code for IR control.
(DevCd)
9. KEY FUNCTION – Select Keypad function.
(KeyFn)
10. SAVE CHANGES? – Select “yes” to save the changes.
(Save?)
LEARN IR (LrnIR)
This procedure allows IR commands to be learned into the system and be centrally stored in the main
controller to let the system access the same IR codes that operate the source equipment.
NOTE: IR codes must be learned in by pointing the remote at the CAM6.6’s REAR panel IR receiver
only.
See Learn IR - Flow Chart page 77
1. LEARNED SRC – Select the source (Source 1-6 and Miscellaneous Learned IR
(LnSrc) (Misc)) whose commands will be learned into the controller.
64