63
All sources that have power management enabled are initialized by a “POWER ON” command/ macro.
Power management is initialized when the first keypad is turned on or when the home theater trigger
input has 12VDC present. The 12VDC trigger output is turned on when the first zone is turned on.
All sources that have power management enabled are turned off by the “POWER OFF” command after
all zones have been turned off, with a timeout of five minutes.The 12VDC trigger output is turned off
one minute after that. This timeout is postponed for as long as the home theater trigger input has
12VDC present.
See Power Management - Flow Chart page 76
1. SOURCE NUM – Select the source number this feature will be configured for.
(Src #)
2. POWER ON CMD – Tells the controller to turn on the selected source equipment (by
(OnCmd) SOURCE NUMBER) when any of the UNO System Keypads is
turned on. If “no,” procedure advances to POWER OFF CMD (step 6)
3. COMMAND TYPE – Select the type of source command (e.g., CD, TV, etc.).
(CmdTp)
a. Selected: Learned IR Choose Learned IR if the pre-programmed IR code library does
(LrnIR) not support the source component.
i. LEARNED SRC – Select the learned source bank to be assigned to the source
(LnSrc) component. Procedure advances to KEY FUNCTION (step 5)
b. Selected: Unassigned The Power On command is cleared. Procedure advances to
(Unasg) POWER OFF CMD (step 6)
c. Selected: Default Default selects the same device type and device code previously
(Deflt) setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 5)
d. Selected: Macro: (To build macros, see Macro Editor page 65)
i. MACRO - Macro loads a series of commands which are processed when
(Macro) activated.
ii. MACRO ID – Enter the macro ID number. Menu advances to POWER OFF CMD
(MacID) (step 6)
e. All Other Selections: Procedure advances to DEVICE CODE (step 4)
4. DEVICE CODE – Source component code for IR control.
(DevCd)
5. KEY FUNCTION -- Select a function (Play, Enter, etc.).
(KeyFn)
INSTALLER