8.0 RZB-ZMD16C-ZDK Board Specifications
8.1. Hardware Specifications
Table 8-1
Table 8-1: RZB-ZMD16C-ZDK Board Specifications
lists the specifications of the RZB-ZMD16C-ZDK Board.
Item Specification
MCU M30280FAHP
Clocks Main Clock: crystal 10 MHz, PLL, or ring oscillator
Sub Clock: 32.768 kHz crystal
Memory
(ICD)
RAM: 8kB (8064 Bytes user available due to kernel)
High E/W Data Block: 2kB × 2 (4096 Bytes)
Flash ROM: 96kB (94kB user available due to kernel)
Connectors [J1-J4]: Four 2×10-pin measurement test points connected to the MCU
pins. Can also be used to connect your own expansion boards via 2×10
headers.
[J7]: In-Circuit Debug connector (UART1 for FoUSB-ICD)
[P1]: 9-Sub-D RS232 connected via RS232 transceiver to UART2
Jumpers [JP1]: MCU Power for Icc Measurements
[JP2]: Power LED and RS232 Power connect
Switches [S1]: pushbutton (connected to P10_4)
[S2]: pushbutton (connected to P10_5)
[S3]: pushbutton (connected to P10_6)
[S4]: pushbutton (connected to Reset)
[SW1]: Power source select switch. If set toward the ICD connector: power
provided by ICD. If set toward the power connector: power provided via
power connector.
LEDs [D1] (Red): User output (connected to P3_4)
[D2] (Yellow): User output (connected to P3_5)
[D3] (Green): User output (connected to P3_6)
[D4] (Red): Power On (if jumper JP2 shorted)
LCD 2-line × 8-character LCD with KS0066 controller IC
8.2. Power Supply Requirements
The RZB-ZMD16C-ZDK Board will draw about 35mA with no LEDs on. With the ICD powered from the
board, the current draw will be about 85mA.
The board has a 3.3V low dropout voltage regulator with an input voltage range from 3.4V to 16V.
8.3. Operating Environment
Table 8-2
Table 8-2: Operating Environment
lists the environmental conditions for using and storing the RZB-ZMD16C-ZDK board. Store the
board in a conductive bag inside the original factory packaging box.
Environmental Condition Ambient Temperature Ambient Humidity
Operating 0 - 55°C
(No corrosive gas allowed)
30 to 80% (non-condensing)
Storage -30 to 75°C
(No corrosive gas allowed)
30 to 80% (non-condensing)
RZB-ZMD16C-ZDK User’s Manual Rev 1.2 20/ 33 August 2006