Applications Engineering
6.11. Customization of Demo Program Settings
The following definitions can be changed at the top of the ZDK_Demo.c file to fit your requirements.
/* ZigBee Configuration */
#define DEMO_CHANNEL 1
#define SCAN_CHANNELS ((DWORD)0x1 << DEMO_CHANNEL) /* Only scan our demo
channel */
//#define SCAN_CHANNELS 0x7FFF800 /* Scan every channel */
ZbPANId s_LocalPanId = 0x1ACE; /* MUST BE A VALUE LOWER THAN 0x3FFF */
/* ASCII Input */
#define MAX_SERIAL_INPUT 20
/* Address Book */
// This array holds the addresses of all the nodes currently
// on the network. It is updated only by the coordinator.
#define MAX_BOOK_ENTRIES 32
/* RECEIVE BUFFER */
#define RX_BUFF_SIZE 256 /* Circular buffer size for data payload (all
data is held in this one buffer) */
#define RX_BUFF_ENTRIES 16 /* Number of buffered packet that can be
queued up */
6.12. Other Limitations
The RZB-ZMD16C-ZDK provides sophisticated debugging features at a low cost, but it does have some
limitations when used with the HEW software debugger and ICD. Those limitations are described in more
detail in the RZB-ZMD16C-ZDK User manual (Start > (All) Programs > Renesas > RZB_ZMD16C_ZDK >
All Manuals and Documents).
RZB-ZMD16C-ZDK User’s Manual Rev 1.2 16/ 33 August 2006