Panasonic WJ-ND400 CD Player User Manual


 
Event
41
Use the following procedure to configure settings that control command alarm action when an event occurs.
1 Click the [Event] button on the setup menu.
2 On the sub-menu that appears, click [Command alarm].
This will display the command alarm setting window.
3 Configure the settings for each item.
Refer to “Command alarm settings” table for details about the
settings.
To configure the settings of a command alarm that is not
shown on the display, click the applicable command alarm
number range above the [Set] button to change the
contents of the display.
Clicking a command number saves the currently
displayed command settings.
4 Click the [Set] button.
Command alarm settings
Initial default
Command alarm
Item Settings Description
Rec. cam. Cam.1 to Cam.64 / -- Specifies the channel of the recording camera.
Preset position Number input
(Blank)
Specifies the preset position (1 to 256) during alarm input.
When this setting is blank, the camera does not move to a
preset position.
Output terminal Off / On Specifies whether an alarm signal should be output when an
event occurs.