Onkyo HT-R640 Stereo Receiver User Manual


 
64
Advanced Setup—Continued
Speaker Level Calibration
Here you can adjust the level of each speaker with the
built-in test tone so that the volume of each speaker is the
same at the listening position.
Note:
The speakers cannot be calibrated while the output of the
AV receiver is muted or while a pair of headphones is
connected.
Note:
This procedure can also be performed by using the
remote controller. First press the [TEST TONE] button
to output the test tone. Use the [LEVEL] and
[LEVEL+] buttons to set the volume, and use the [CH
SEL] button to select the speakers.
1
Press the [RECEIVER] or [AMP]
button followed by the [SETUP]
button.
The main menu appears onscreen.
MUTING
PREVIOUS
MENU
GUIDE
TOP MENU
SETUPRETURN
PLAYLIST/CAT PLAYLIST/CAT
--
/
---
TAPE/AMP
M
D/CDR
HDD
CABLE
STANDBY/ON
DIMMER
ENT
D TUN
SLEEP
10 11 12
INPUT SELECTOR
REMOTE MODE
V1
V4
V2 V3
C
DTAPE TUNER
DVD
MULTI CH
TV
VOL
VOL
SAT
VCR
TV
DVD
RECEIVER
C
D
INPUT
+
10
0
CLR
123
456
789
ENTER
CH
DISC
ALBUM
1, 5
2, 3
2
1
RECEIVER
AMP
SETUP
2
Use the Up and Down [ ]/[ ]
buttons to select 3. Level Cali-
bration, and then press
[ENTER].
The Level Calibration menu appears
and the pink noise test tone is output by
the front left speaker.
Note:
Speakers that you set to No or None on
the Speaker Conguration page
(page 42) cannot be selected.
3
Use the Up and Down [ ]/[ ]
buttons to select each speaker,
and use the Left and Right [ ]/
[ ] buttons to set the volume.
The volume can be adjusted from 12
to +12 dB in 1 dB steps (15 to +12 dB
for the subwoofer).
4
Repeat step 3 until the volume of
the test tone from each speaker
is the same.
5
Press the [SETUP] button.
The setup menu closes.
3.Level Calibration
------------------------
a.Left : 0dB
b.Center : 0dB
c.Right : 0dB
d.SurrRight : 0dB
e.SurrLeft : 0dB
f.Subwoofer : 0dB
SETUP