Mitsubishi Electronics A951GOT Stereo Equalizer User Manual


 
8 - 11
8.3 Wiring Precautions the Part which Matches the EMC Directives
8.3.2 Grounding the ground cable
8.3.2 Grounding the ground cable
Manufacture the cable used with the GOT with the following method.
When manufacturing the cable, a ferrite core, cable clamp and cable shielding material are required.
The cable clamp used by Mitsubishi Electric for the EMC specification compatibility test is shown below.
TDK brand ZCAT3035-1330 Ferrite Core
Mitsubishi Electric Model AD75CK cable clamp
Japan Zipper Tubing Co., Ltd. Zipper tube SHNJ type
(1) Bus Connection
(a) For A8GT-C100/200/300EXSS
Cut the ground wire from the core where it protrudes from both ends of the cable.
Peel the sheath (with the length shown below) at both ends of the cable, and expose the
shield braided wire for grounding.
(b) For A8GT-C100/200/300BS
ٛ
Cut the ground wire from the core where it protrudes from both ends of the cable.
Cut
Ground wire
130
(5.12)
130
(5.12)
GOT side
Within 360
40
Unit: mm (inch)
Ferrite core
(ZCAT3035-1330)
PLC side
40
(1.57)
Within 360
(14.17) (1.57) (14.17)
Cut
Ground wire