HP (Hewlett-Packard) HP 37718A Satellite Radio User Manual


 
9
Setting the Interfaces
Setting Wander Transmit Interface
Setting Wander Transmit Interface
Description: You can add Wander to the 2 Mb/s DSn signal and the STS-3, OC-3,
OC-12 or OC-48 SONET signal.
HOW TO: DSn Wander (2 Mb/s)
1 Connect REF OUT on the SONET Clock module to REF IN on the DSn
Jitter TX module (this provides the Wander Reference).
2 Set up the DSn transmit interface, choose CLOCK SYNC and
select the SOURCE required from the menu. See “Setting DSn
Transmit Interface” page 2.
3 Choose JITTER/WANDER .
If you wish to add jitter to the DSn signal, See “Setting Jitter Transmit
Interface” page 7.
4 Choose WANDER .
5 Choose the modulation source.
If is chosen, connect the external source to the MOD IN
port of the DSn Jitter TX module. Up to 10 UI of external wander
modulation can be added.
2M REF
WANDER
ON
EXTERNAL