Bogen PM-3180 Stereo Amplifier User Manual


 
Programming
Note: Press and hold arrow buttons to effect rapid changes in
volume. Quick presses of the buttons will effect single-step
changes in volume.
5. Once you have set the desired volume for an input, press ENT. The
PROG light will blink to indicate that the data was stored.
6. At this point, you can select another amp/channel-input combination
and repeat Steps 4 and 5 to set other volume levels. You can also
select the BASS or TREB control and set the levels for these controls.
When you press the BASS or
TREB button. the display shows
the current amp/channel-input
combination and preset level (-7
to +7, corresponding to the
amount of cut or boost; 0 is the
default).
Press the arrow buttons to
increase/decrease the tone control. The level num-
ber will increase or decrease, and the pointer will
move left or right in response to the changes made.
Remember to press ENT after setting each level.
7. Once all levels are set, press EXIT to return to the function menu. At
this point you can exit the programming mode or press NEXT or BACK
to select another function.
Note: You should preset the level and tone for all inputs, even
those that are not assigned to an amp channel. This is
because a user can select an unassigned input using the manu-
al input selection feature.
A1/AUX A-0
29