Installation
RS-900 and RS1100 Series Installation/Operation Manual 37
PRE
L
IMINAR
Y
Connecting to AC PowerProjector: The RS-900/RS1100
ships with various types of AC
power cords. Choose the one that
is appropriate to your locale.
Plug the female end of the power
cord into the AC receptacle on the
rear of the projector (AC 100V ~
240V). Then, connect the other end
to your AC power source.
AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power
cord is provided for the lens motor. Plug the female end of the AC power cord into the AC
input on the rear of the lens motor assembly. Connect the other end to a 110
VAC power
source.
3.7
Turning on the Power
1. Turn on your source components.
2. If this is an AutoScope-equipped projector, turn on the main power switch at the rear
of the AutoScope lens motor. The lens motor power switch is located next to the AC
input (see above).
3. Turn on the main power switch at the rear of the projector. The POWER LED lights
orange. The LAMP and TEMP LEDs light red briefly, then go out.
4. Press the ON button on the remote control to turn on the RS-900/RS1100. The
POWER LED flashes green to indicate that it is warming up.
5. When the projector is ready for use, the POWER LED lights solid green.
6. “[Input Name] Source Searching” appears on the screen before the RS-900/RS1100
identifies the input signal and remains there until a valid signal is detected.
The input voltage to the AutoScope lens motor must be between
100 and 120 VAC. Do not connect the AutoScope lens motor
to a 200-240
VAC power source!
Power
switch
Caution
AutoScope Lens Motor (Rear)
AC Input
Power
Switch
to
110 VAC
Power