Rotel RSX-1056 Stereo Receiver User Manual


 
45
English
Specifications
Audio
Continuous Amplifier Power
(five channels driven)
75 watts/ch (20-20k Hz, <0.05% THD, 8 ohms)
Continuous Amplifier Power
(two channels driven)
100 watts/ch (1kHz, <1.0% THD, 8 ohms, DIN)
Total Harmonic Distortion
<0.09%
Intermodulation Distortion (60 Hz:7 kHz)
<0.05%
Frequency Response
10 Hz – 120 kHz, ±3dB (analog bypass)
10 Hz – 95 kHz, ±3dB (digital input)
Signal to Noise Ratio (IHF A-weighted)
95dB (analog bypass)
92dB (Dolby Digital, dts) 0dBFs
Input Sensitivity/Impedance
Line Level: 200 mV/100K ohms
Preamp Output Level/Output Impedance
1.0 V / 1K ohms
Contour (LF/HF)
±6dB at 50 Hz/15 kHz
Decodable Digital Input Signals
Dolby Digital, Dolby Digital EX, DTS, DTS-ES,
DTS 96/24, LPCM (up to 192K), HDCD, MP3,
MPEG Multichannel
Video
Frequency Response
3 Hz – 10 MHz, ± 3dB (Digital Input)
3 Hz – 100 MHz, ± 3dB (Component Video)
Signal to Noise Ratio
45dB
Input Impedance
75 ohms
Output Impedance
75 ohms
Output Level
1.0 volt
FM Tuner
Usable Sensitivity
14.2dBf
Signal to Noise Ratio (at 65dBf)
70dBf
Harmonic Distortion (at 65dBf)
0.03%
Stereo Separation (1 kHz)
45dB
Output level
1 V
Antenna Input
75 ohms unbalanced
AM Tuner
Sensitivity
500 µV/m
Signal to Noise Ratio
40dBf
Output level
500 mV
Antenna Input
Loop Antenna
General
Power Consumption:
450 watts
78 watts (idle)
8 watts (standby)
Power Requirements (AC)
115 volts, 60Hz (USA version)
230 volts, 50Hz (CE version)
Weight
17.2 Kg/37.8 lb.
Dimensions (W x H x D)
432 x 162 x 442 mm
17.01" x 6.38" x 17.40"
Front Panel Height
(feet removed/for rack mount)
150 mm / 5.91"
When sizing openings in custom cabinets, measure
the unit to be installed and/or allow at least 1 mm
clearance on all sides for unit to unit tolerances.
All specifications are accurate at the time of
printing. Rotel reserves the right to make improve-
ments without notice.
Rotel and the Rotel HiFi logo are registered
trademarks of The Rotel Co, Ltd., Tokyo, Japan.