Rotel RSP-1069 Stereo Receiver User Manual


 
44
RSP-1069 Surround Sound Processor
Miscellaneous Settings
Other Options











This OTHER OPTIONS menu, accessed from
the MAIN menu, provides access to several
miscellaneous settings as follows:
RECORD: Select which source signal to be
sent to the recording outputs by choosing one
of the input sources. The options are: CD,
TAPE, TUNER, VIDEO 1–5, and SOURCE.
You can either select a specific component
or select SOURCE which will send the signal
to the record outputs from whatever source
is selected for listening.
TURN ON VOL: Specifies a default volume
level to be used each time the RSP-1069 is
activated. You can select LAST to have the
RSP-1069 power up with the last previously
used volume setting. Or, you specify a vol
-
ume from MIN (full mute) to MAX, in 1dB
increments. Note that this setting cannot ex-
ceed the MAX VOL established in the next
line of the menu.
MAX VOL: Specifies the maximum volume
level for the RSP-1069. The volume cannot be
adjusted above this level. Settings range from
MIN to MAX, in 1dB increments.
POWER: This setting determines how the
RSP-1069 powers up.
With the default STANDBY setting, the unit
powers up in standby mode when AC is ap
-
plied and the rear panel POWER button is
ON. The unit must be activated using the
front panel STANDBY button or the remote
ON/OFF buttons.
With the DIRECT setting, the unit is fully ac
-
tivated when AC power is applied and the
rear panel POWER button is ON; however,
it may be put in standby mode using the front
panel STANDBY button or the remote ON/
OFF buttons.
In ALWAYS-ON mode, the unit remains fully
active whenever AC is present and the rear
panel POWER button is ON; the front panel
STANDBY button and the remote ON/OFF
buttons are disabled and the unit cannot be
put in standby mode.
In RESUME mode, the RSP-1069 will return to
the last power condition setting when switched
on. For example, when the AC mains power
is switched OFF during operation, it will return
to operating mode when the mains power is
switched on again.
LANGUAGE: Selects a language for the
On Screen Display.
DISCRETE: The default setting of NO al
-
lows control of volume and input selection
in remote zones 2–4 from the main room
remote control. Changing the setting to YES
prevents the remote control in the main room
from affecting any other zone in any way,
even when the RSP-1069 is in zone mode
following a change to a zone.
The discrete option does not affect the con-
trol of the zones from the front panel buttons
in any way.
NOTE: The DISCRETE function is not available
on all models and is dependent on the software
version installed. The DISCRETE is intended for
use by a Rotel dealer or installer only.
Rotel’s use of discrete IR commands in multi-
zone models provides easier integration with
IR control systems, making control possible
from a single IR input. For Rotel dealers or
installers, further information is available on
the Rotel website:
www.rotel.com
Go to ‘Support’ for downloads and tech-
nical updates, or seach for ‘discrete’ to
find relevant items. Remote commands are
available in Philips Pronto CCF format and
in RTI CML format at:
www.rotel.com/downloads/prontocodes.htm
www.rotel.com/downloads/rticodes.htm
MAIN UPGRADE: Allows the RSP-1069‘s
main operating software to be upgraded as
additional capabilities are developed. Se-
lect NO for normal operation. Select YES
to go to a special FLASH UPGRADE MODE
that rewrites the operating software from
a computer connected to the back panel
COMPUTER I/O port. This feature should
only be performed by qualified personnel.
We strongly recommend having your Rotel
Dealer perform this upgrade.
NOTE: After performing the software upgrade,
turn off the RSP-1069. Then, turn it back on
to return to normal operation.
Change settings on the OTHER OPTIONS
menu by highlighting the desired line using
the UP/DOWN buttons and using the +/– but
-
tons to step through the available settings. To
return to the MAIN menu, press the ENTER
button. Press the MENU/OSD button on the
remote to cancel the display and return to
normal operation.
VIDEO/HDMI







This VIDEO/HDMI menu, accessed from the
MAIN menu, provides access to several im
-
portant video settings as follows:
VIDEO OUT FORMAT: Specifies the vid
-
eo resolution and format of the video output
at the TV MONITOR outputs. The RSP-1069
will scale all video inputs up to this specified
resolution for a perfect match with the native
resolution of your HDTV monitor. Can be
480p/576p, 720p, 1080i, 1080p.
HDMI AUDIO MODE: HDMI video ca
-
bles can carry audio signals from a source
component. This setting determines whether
those audio signals are passed along to the
TV monitor. Choose the default AMP mode
to stop the audio signals from being passed
to the TV. Choose TV Mode to pass the au
-
dio signals to the TV.
VIDEO UPGRADE: Allows the RSP-1069‘s
video processing software to be upgraded
as additional capabilities are developed.