K-Tec MT2000 Satellite Radio User Manual


 
34 MT2000-0200-01 Rev f (10-2007)
DCN0160
9.9 APPENDIX I: Mounting Configurations
External
Chamber
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
1.7 20 ft./6.1 m
3 30 ft./9.1 m
10 50 ft./15.2 m
35 50 ft./15.2 m
Coaxial
Probe
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
1.4 20 ft./6.1 m
4 20 ft./6.1 m
10 100 ft./30.5 m
Dual Rod
Flat Plate Or
Coupling
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
3 20 ft./6.1 m
4 20 ft./6.1 m
10 100 ft./30.5 m
Dual Rod
Nozzle &
Flange
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
2.5 20 ft./6.1 m
4 20 ft./6.1 m
10 100 ft./30.5 m
Flat Plate
Or
Coupling
Nozzle
&
Flange
Permanent
Stilling Well
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
4 20 ft./6.1 m
10 40 ft./12.2 m
35 100 ft./30.5 m
1.3
1
100 ft./30.5 m
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
4 20 ft./6.1 m
10 40 ft./12.2 m
35 100 ft./30.5 m
1.3
1
100 ft./30.5 m
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
1.7 20 ft./6.1 m
3 30 ft./9.1 m
10 50 ft./15.2 m
35 50 ft/15.2 m
MINIMUM
DIELECTRIC
CONSTANT
MAXIMUM
PROBE
LENGTH
1.7 20 ft./6.1 m
3 30 ft./9.1 m
10 50 ft./15.2 m
35 50 ft/15.2 m
Removable
Stilling Well
1. Accuracy subject to changes in dielectric constant. Ultra-Low Dielectric (ULD) measurement method supports dielectric
constants from 1.3 to a maximum of 2.0.
1, 2
7
6
5
4 3a, 3b
9, 10a,
10b
8
Figure 9.4